Ontario government not measuring wind turbine noise effectively, engineer tells international conference

22 Monday May 2017

Posted by ottawawindconcerns in Health, Renewable energy, Wind power

≈ 1 Comment

Tags

environmental effects wind farms, MOECC, Ontario government, renewable energy, tonal noise wind turbines, William Palmer, wind farm, wind farm noise, wind turbine, Wind Turbine Noise 2017, Wynne government

Noise measurement protocol needlessly complex, failing to identify critical issues with wind turbine noise, Ontario engineer says.

He used MOECC data to confirm “tonal” quality to wind turbine noise emissions. One project has been operating for eight years — residents continue to complain, no action by Ontario government

Conference venue in Rotterdam: Wind Turbine Noise 2017

Ontario engineer William Palmer has proposed a rigorous, but simple and transparent technique to assess wind turbine noise, that could replace the problematic complex computer models and “black box” algorithms currently used in the Ontario Ministry of the Environment and Climate Change newest protocol to assess wind turbine noise compliance.

Speaking at the International Conference on Wind Turbine Noise that took place in Rotterdam beginning May 2, Palmer said of his proposed method,

The method had to consider that an effective monitoring system must take into account more than just averaging sound power levels over a long term. The method recognizes that humans are bothered by the changes and annoying characteristics that occur, as well as long term averages. Others describe this as the need to determine how the special characteristics of sound quality may impact quality of life.

To verify this approach, assessments were conducted using the method at two wind power developments in Ontario. In the K2 Wind project, he used MOECC data from testing in early March 2017 at a home within the K2 project. He was able to demonstrate that the MOECC data confirmed that the noise from the turbines surrounding the home had a tonal quality; that means it should require a 5 dB(A) penalty be applied to the other test results.

He reported:

Although the Ministry did not provide calibration files for their sound recordings they did provide in their report their assessment of the sound pressure level for each sample. Using the Electroacoustics Toolbox, and working backwards to set the given sound pressure level for a number of the recordings provided as the calibration level, permitted a “Quasi Calibration” of the Ministry data, and from that a calibrated FFT analysis was made. … Again, it was seen that when the residents described adverse effects in their comments filed with their initiation of recordings, FFT analysis of the sound recordings taken at those times clearly show a tonal condition occurring at about 450 Hz.

In the Enbridge project, where Mr. Palmer also conducted testing, he found similar tonal quality to the noise emissions in that project, and confirmed that the noise coming from the turbines is above the approved levels at several locations.

For this facility as an example, where the turbines first went into operation in November 2008, and citizen complaints occurred soon after, it has not yet been possible to complete a report to demonstrate compliance. The monitoring is still in progress, over 8 years later, with the turbines continuing in operation, and residents continuing to complain. The hypothesis is that individual samples are not representative due to variation.

Process is complex

He offered comment on the current protocol being used to assess compliance by the MOECC:

A premise of the Ministry of the Environment and Climate Change wind turbine monitoring protocol is that monitoring to show compliance must be conducted over a long period. The protocol requires the initial acoustic monitoring by residents to produce at least a 10-minute sample for each complaint period, and the final compliance protocol requires a minimum of 120 one-minute measurement intervals for each integer of wind speed. During each of those one-minute intervals there must be no changes in wind speed or direction. A further 60 samples are required for each integer wind speed with the turbines not operational. So far data collection has taken years to obtain a sufficient number of samples, and in at least one array, initial reports showed that over 90% of samples taken were discarded as non-compliant. All samples are logarithmically combined to determine the Leq produced by the facility, which eliminates any short-term change effects. This appears to be precisely the sort of monitoring that was cautioned against by Genuit and Fiebig described in Section 1 when they noted, “By relying on sound pressure levels averaged over long time periods and suppressing all aspects of quality, the specific properties of environmental noise situations cannot be identified, because annoyance caused by environmental noise has a broader linkage with various acoustical properties such as frequency spectrum, duration, impulsive, tonal and low-frequency components, etc. than only with SPL [Sound Pressure Level]. In many cases these acoustical properties affect the quality of life.”

The annoyance aspects that impact the quality of life of impacted residents are not being assessed.

People walking away from loved homes

The current protocol cannot possibly identify critical issues in wind turbine noise emissions, Palmer asserts. In conclusion, he said:

This paper has demonstrated a method for rigorous monitoring of wind turbine sound. The goal of the method was to establish evidence for the condition noted by Karl D. Kryter: “The most direct, and perhaps most valid, insight into the possible presence and magnitude of stress reactions in general living environments is probably that which has been obtained from attitude surveys and real-life behaviour of people.” Behaviours such as walking away from an unsold loved home to live at the home of a family member, or when normal people become activists in trying to communicate their concerns provide such valid insights. The rigorous method had to consider the present acceptance criterion for wind turbines, in light of the insight given by those who study the quality of noise and its relation to annoyance. Those who study the subject identify that, “Current acceptance criterion relying on sound pressure levels averaged over long time periods and suppressing all aspects of quality cannot identify the specific properties of environmental noise situations.”

The results reported by Bill Palmer are typical of the community testing being undertaken in many communities near wind turbine projects across Ontario.

These findings indicate that the complex processes used by the MOECC and required of wind companies for compliance testing fail to identify key issues that can be quickly identified using much simpler techniques.

Meanwhile, the turbines, shown by other methods to be out of compliance, continue to operate.

[Re-posted from Wind Concerns Ontario]

New wind turbine noise guidelines fail to address problems

26 Wednesday Apr 2017

Posted by ottawawindconcerns in Health, Renewable energy, Wind power

≈ 1 Comment

Tags

community opposition wind farm, Glen Murray, infrasound wind turbines, low frequency noise, MOECC, Ontario, Ontario Ministry of the Environment and Climate Change, renewable energy, tonal noise wind turbines, wind farm, wind farm noise, wind farm siting, wind mill, wind power, wind turbine, wind turbine noise

New Ontario wind turbine noise compliance protocol falls short

Way short.

As in, little or no understanding of the problems with wind turbine noise emissions.

New noise protocol misses all the problems

 

On Friday, April 21, the Ministry of the Environment and Climate Change released a new protocol document intended for “assessing noise from wind turbines that have already been built. It is used by industry and ministry staff to monitor compliance.”

While in the absence of guidance for staff, and the complete lack of compliance audit information from wind power developers and operators, this is a step forward, the truth is, the protocol doesn’t change much.

Here’s why:

  • the protocol still relies on audible noise only, when many of the complaints registered with the MOECC concern effects that are clearly linked to other forms of noise
  • the protocol does not take into account lower wind speeds, which is where problems are being experienced, particularly with newer, more powerful turbines
  • there is no comment on any sort of transition between the protocol that existed before and this one

Improvements:

  • the Ministry’s action in producing this protocol is an indication that they know they have a problem
  • the description of Ministry response is a good step forward
  • requiring wind power companies to actually have, and to publish, compliance audit documents could be a sign of expectations of greater accountability among the power developers/wind power project operators.

This table outlines the critical gaps in the new protocol document.

 

Issue     Protocol Requirements Actual Experiences
Wind Speeds Assessment of noise at wind speeds between 4 m/s and 7 m/s MOECC testing indicates problem noise starts below 3 m/s which is outside of wind speeds involved in the protocol.
Ambient Noise Narrow time period assessed Wide seasonal variations while wind turbine noise constant
Location Only test outside of home Very different inside noise conditions
Tonal Assessments Uses criticized techniques Narrow band analysis shows tonal noise present.
Resident Input None Resident concerns drive other MOECC procedures
Frequencies Excludes Infrasound Elevated levels of infrasound in homes

 The Ministry of the Environment and Climate Change needs to acknowledge that there is a problem with wind turbine noise, and accept that it must play a role as a government agency charged with protecting the environment and people in it — preparing an industry-led document may look like a positive step, but this document does not meet the needs of the people of Ontario forced to live with wind turbines, and their noise emissions.

Wind Concerns Ontario

Recent Posts

  • Ottawa environment committee votes Yes to wind on City-owned lands
  • City environment committee to hear motion tomorrow on wind turbines on public land
  • Put distance between wind turbines and homes, Ottawa Wind Concerns tells City
  • Ontario government lags on wind turbine regulations: Ottawa business newspaper
  • Ottawa renewable energy future “predominately wind and solar” says city staff

Follow me on Twitter

My Tweets

Enter your email address to follow this blog and receive notifications of new posts by email.

Tags

Bob Chiarelli electricity bills Ontario Green Energy Act IESO Ontario Ottawa wind concerns wind farm wind farms wind power wind turbines

Contact us

PO Box 3 North Gower ON K0A 2T0

Create a free website or blog at WordPress.com.

Privacy & Cookies: This site uses cookies. By continuing to use this website, you agree to their use.
To find out more, including how to control cookies, see here: Cookie Policy
  • Follow Following
    • Ottawa Wind Concerns
    • Join 1,083 other followers
    • Already have a WordPress.com account? Log in now.
    • Ottawa Wind Concerns
    • Customize
    • Follow Following
    • Sign up
    • Log in
    • Report this content
    • View site in Reader
    • Manage subscriptions
    • Collapse this bar
 

Loading Comments...