Tags

, , , , , ,

Ministry of Environment noise study for wind power project was done using average wind speed at a “particularly quiet site” says consultant hired by Kincardine: increase in sound from wind alone is “staggering”

(Re-posted from Wind Concerns Ontario)

Kincardine Independent, February 24, 2016

GROUNDBREAKING INFRASOUND STUDY RESULTS UNVEILED

By Barb McKay

An acoustics engineer is questioning the Ontario government’s methods for setting baseline sound limits for wind turbines after field testing was recently conducted in Kincardine.

Todd Busch, project manager for Swallow Acoustic Consultants Ltd., was in front of the Municipality of Kincardine council during its meeting last Wednesday to go over data from a study conducted within the boundaries of the Armow Wind Project last fall. Swallow was contracted by the municipality to study baseline acoustic and infrasound levels prior to the 92-turbine, 180-megawatt project becoming operational.

Engineers conducted interior and exterior sound testing at five homes within the project area between Oct. 30 and Nov. 14, 2015, using special microphones designed specifically to record infrasound (sound not picked up by the human ear). The sound measurements account for sound levels from wind in exterior testing.

Busch said when a noise impact study was conducted with audible sound testing for Armow Wind in 2013, engineers who did the study declared that the project would comply with Ontario Ministry of the Environment noise limits for industrial wind turbines. He said the study was done using an average wind speed at a particularly quiet site and a measurement of seven decibels was added to factor in sound levels at a higher wind speed. In the noise impact assessment summary, Busch said sound levels were calculated at between 37 and 39.8 decibels. The noise level limit set by the province is 40 decibels. Infrasound levels were not tested.

Busch said the report that was generated from the noise impact study did not explain why seven decibels was assumed for higher wind speeds and he questions the mehodology used to measure residual noise levels in the background environment. He does not believe the study factored in noise levels associated with wind and therefore is concerned the testing was compromised.

“We placed our microphones within 10 metres of where the noise impact assessment (study) microphones would have been,” Busch said. “A measurement of 39.8 decibels would be a candidate for scrutiny.”

Testing by Swallow generated acoustic sound levels of between 37 and 57 decibels outdoors and 20 to 40 decibels indoors. Infrasound levels measured between 57 and 88 decibels outdoors and 53 to 72 decibels indoors. He said the increase in sound from wind alone is staggering and should be explored further.

“We have been told many times from the provincial government that we can’t measure infrasound,” councillor Randy Roppel said. “Can you?”

“We did,” Busch replied.

Read the full story here

Advertisement